Product Description



Applications
Power supply for those unmanned regions like mobile communication station, high way, the coastal islands, remote mountainous regions and border posts. Regional research projects, government demonstration projects, landscape lighting projects for those places with insufficient power or power shortages.
Features
Apply for independent wind &solar hybrid system, lighting system and monitoring system. LED Display
Specification
Model |
WWS02-12B |
WWS04-24B |
WWS06-24B |
Wind Turbine Input |
Rated input power |
200W |
400W |
600W |
Rated input voltage |
14Vdc |
28Vdc |
28Vdc |
Input voltage range |
28Vdc |
0~32Vdc |
0~32Vdc |
Rated input current |
17Adc |
17Adc |
25Adc |
PV Input Parameters |
Rated input power |
100W |
200W |
200W |
Max. open circuit voltage |
24V |
48V |
48V |
Reversed connection protection |
YES |
Charge Parameters |
Rated battery voltage |
12V |
24V |
Output Parameters |
Rated output voltage |
12V |
24V |
Output overvoltage point |
14.5V (factory default,11Vdc~16Vdc settable) |
29V (factory default,22Vdc~32Vdc settable) |
Output overvoltage recovery point |
13.2V (factory default, reduce 1.3V from the output overvoltage point) |
26.4V (factory default, reduce 2.6V from the output overvoltage point) |
Max. Output current |
17A |
17A |